Fire control plan symbols The Fire Control Plan hangs at the companionways, and a copy sits in a marked container on the accommodation bulkhead, usually right at the entrance: that is the red tube a shore fire brigade reaches for when boarding. These 52 symbols are the legend of that plan: they say where the fire dampers, pumps, section valves and the spaces protected by fixed installations are. It is technical graphics drawn onto the ship's plan, without the normative background colours and board shapes of wall signs.
Plans 3 Fire control plan SIS001 SVG Safety plan SIS002 SVG Fire and safety plan SIS003 SVG Ventilation and closures 18 Ventilation remote control or shut-off (accommodation and service spaces) SIS004 SVG Ventilation remote control or shut-off (machinery spaces) SIS005 SVG Ventilation remote control or shut-off (cargo spaces) SIS006 SVG Remote control for skylight SIS007 SVG Remote control for watertight doors SIS008 SVG Remote control for fire doors SIS009 SVG Fire damper (accommodation and service spaces) SIS010 SVG Fire damper (machinery spaces) SIS011 SVG Fire damper (cargo spaces) SIS012 SVG Remote control for fire damper (accommodation and service spaces) SIS013 SVG Remote control for fire damper (machinery spaces) SIS014 SVG Remote control for fire damper (cargo spaces) SIS015 SVG Closing device for ventilation inlet or outlet (accommodation and service spaces) SIS016 SVG Closing device for ventilation inlet or outlet (machinery spaces) SIS017 SVG Closing device for ventilation inlet or outlet (cargo spaces) SIS018 SVG Remote control for closing device for ventilation inlet and outlet (accommodation and service space) SIS019 SVG Remote control for closing device for ventilation inlet and outlet (machinery spaces) SIS020 SVG Remote control for closing device for ventilation inlet and outlet (cargo spaces) SIS021 SVG Pumps 8 Remote control for fire pump(s) SIS022 SVG Fire pump(s) SIS023 SVG Remote control for emergency fire pump or fire pump supplied by the emergency source of power SIS024 SVG Emergency fire pump SIS025 SVG Fuel pump(s) remote shut-off SIS026 SVG Lube oil pump(s) remote shut-off SIS027 SVG Remote control for bilge pump(s) SIS028 SVG Remote control for emergency bilge pump SIS029 SVG Valves and connections 10 Remote control for fuel oil valves SIS030 SVG Remote control for lube oil valves SIS031 SVG Remote control for fire pump valves SIS032 SVG International shore connection SIS033 SVG Fire hydrant SIS034 SVG Fire main section valve SIS035 SVG Sprinkler-section valve SIS036 SVG Powder-section valve SIS037 SVG Foam-section valve SIS038 SVG Water spray system valves SIS040 SVG Extinguishing installations and protected areas 8 High expansion foam supply trunk (outlet) SIS039 SVG Inert gas installation SIS041 SVG Space or group of spaces protected by a water fire-extinguishing system SIS042 SVG Space or group of spaces protected by a foam fire-extinguishing system SIS043 SVG Space or group of spaces protected by a gas other than CO2 fire-extinguishing system SIS044 SVG Space or group of spaces protected by a powder fire-extinguishing system SIS045 SVG Space or group of spaces protected by a CO2 fire-extinguishing system SIS046 SVG Space or group of spaces protected by a sprinkler or high-pressure water fire-extinguishing system SIS047 SVG Emergency power and control 5 Emergency source of electrical power (generator) SIS048 SVG Emergency source of electrical power (battery) SIS049 SVG Emergency switchboard SIS050 SVG Air compressor for breathing devices SIS051 SVG Control panel for fire detection and alarm system SIS052 SVG Set per table 3 of the annex to IMO resolution A.1116(30); graphic patterns per ISO 17631 (adapted from resolution A.952(23)). Files are public domain. This is not a legal text: in any doubt the current wording of the resolution decides.
← All safety signs Signs quiz